Document Type : Research Articles

Authors

Department of Chemical Engineering, University of Sistan and Baluchestan, Zahedan 98164, Iran

Abstract

Objective: The objective of this research is to optimize the crude distillation unit (CDU) in oil refineries by reducing energy consumption and improving operational efficiency through the application of a Proportional-Integral-Plus (PIP) control system within a Non-Minimal State Space (NMSS) framework. Material and Method: Simulations of the CDU were carried out using Aspen Plus for modeling the distillation process and MATLAB for implementing the PIP control structure. The controller was tuned by an economic cost function, optimizing key parameters such as furnace duty, side-draw rates, and condenser heat removal. The PIP control system was compared to traditional control methods, with performance evaluated under various disturbances, including feed rate, temperature, and composition changes. Results: The PIP control strategy significantly improved the CDU’s performance, reducing operating costs by up to 100% compared to traditional control methods optimized by the Integral of Time-weighted Absolute Error (ITAE). The PIP system demonstrated superior disturbance handling and energy efficiency while maintaining product quality. Conclusion: The findings indicate that the PIP control system is a highly effective tool for optimizing energy consumption and process stability in modern refineries, especially under fluctuating operational conditions. Its application could lead to substantial cost savings and improved efficiency in CDU operations.

Keywords

Main Subjects

[1] Zhang, H., Liu, X., and Wang, Y., "Sustainable optimization of crude oil distillation through integrated energy-saving control systems," Energy Reports, vol. 9, pp. 435-450, 2023.

[2] S. Skogestad, “Probably the best simple PID tuning rules in the world,” J. Process Control, vol. 13, no. 4, pp. 291-309, 2007.

[3] M. L. Darby and M. Nikolaou, “MPC: Current practice and challenges,” Control Eng. Pract., vol. 20, no. 4, pp. 328-342, 2012.

[4] S. J. Qin and T. A. Badgwell, “A survey of industrial model predictive control technology,” Control Eng. Pract., vol. 11, no. 7, pp. 733–764, 2003.

[5] E. F. Camacho and C. Bordons, Model Predictive Control. New York: Springer, 2004.

[6] A. Bemporad and D. Muñoz de la Peña, "Multiobjective model predictive control," Automatica, vol. 45, no. 12, pp. 2823–2830, 2009.

[7] W. L. Luyben, Process Modeling, Simulation, and Control for Chemical Engineers. New York: McGraw-Hill, 2006.

[8] F. Sun, T. Liu, B. Song, Y. Cui, Z. K. Nagy, and R.Findeisen, "Multi-objective optimization based nonlinear model predictive control of seeded cooling crystallization process with application to β form L-glutamic acid," Chemical Engineering Science, vol. 299, 2024, 120475. Doi: 10.1016/j.ces.2023.120475.

[9] 9. Alberto Bemporad, David Muñoz de la Peña, "Multiobjective model predictive control," Automatica, vol. 45, no. 12, pp. 2823-2830, 2009. DOI: https://doi.org/10.1016/j.automatica.2009.09.032

[10] Qin, S. J. and Badgwell, T. A., "A survey of industrial model predictive control technology," Control Engineering Practice, vol. 11, no. 7, pp. 733-764, 2003.

[11] G. Dulac-Arnold, R. Evans, P. E. Sountsov, “Challenges of Real-World Reinforcement Learning,” NeurIPS 2019. [DOI: 10.48550/arXiv.1904.12901]

[12] T. Skogestad, "Dynamics and control of distillation columns—a tutorial introduction," Chemical Engineering Research and Design, vol. 75, no. 6, pp. 539-562, 1997.

[13] Kunru Yang, Shirun Liu, Chang He, Bingjian Zhang, Qinglin Chen, Ming Pan, “Improving energy saving of crude oil distillation units with optimal operations,” Journal of Cleaner Production, vol. 263, p. 121340, 2020.

[14] M. M. Khalilipour, J. Sadeghi, F. Shahraki, and K. Razzaghi, “Nonsquare multivariable non-minimal state space-proportional integral plus (NMSS-PIP) control for atmospheric crude oil distillation column,” Chem. Eng. Res. Des., vol. 113, pp. 140–150, 2016, doi: 10.1016/j.cherd.2016.07.018.

[15] C. Taylor, S. Chotai, and P. Young, Proportional-IntegralPlus Control of Multivariable Systems. New York: Springer, 2013.

[16] L. Larsson and S. Skogestad, “Energy efficient control of distillation columns,” J. Process Control, vol. 10, no. 1, pp. 69–77, 2000.

[17] B. Kiani Talaei, F. Shahraki, J. Sadeghi, M. Khalilipour," Optimal metaheuristic state-dependent parameter proportional-integral-plus control: Alternative to gainscheduled controller for control of a nonlinear continuous stirred tank reactor", Systems and Soft Computing, Vol. 5, 20053, 2023.

[18] S. Kharaji, J. Sadeghi, F. Shahraki, and M. M. Khalilipour, “A new control structure for tert-amyl methyl ether production using reactive distillation,” ISA Trans., vol. 97, pp. 53–66, 2020, doi: 10.1016/j.isatra.2019.07.021.

[19] B. Bidar, M. M. Khalilipour, F. Shahraki, and J. Sadeghi, “A data-driven soft-sensor for monitoring ASTM-D86 of CDU side products using local instrumental variable (LIV) technique,” J. Taiwan Inst. Chem. Eng., vol. 84, pp. 49–59, 2018, doi: 10.1016/j.jtice.2018.01.009.

[20] Y. Shin, R. Smith, and S. Hwang, "Development of model predictive control system using an artificial neural network: A case study with a distillation column," Journal of Cleaner Production, vol. 277, p. 124124, 2020, doi: 10.1016/j.jclepro.2020.124124.

[21] L. Li, R. Dixon, E. Stewart, and H. Duan, "Implementation of proportional-integral-plus control to a high redundancy actuator for a track switch system," IFAC-Papers OnLine, vol. 56, no. 2, pp. 4406-4411, 2023, doi: 10.1016/j.ifacol.2023.05.095.

[22] J. Hernández and L. Jiménez, “Energy optimization of distillation columns,” Ind. Eng. Chem. Res., vol. 38, no. 9, pp. 3446–3453, 1999.

[23] W. L. Luyben and B. Tyreus, Process Control and Design for Chemical Engineers. New York: McGraw-Hill, 1998.

[24] T. Kailath, Linear systems, Prentice-Hall EnglewoodCliffs, NJ1980.

[25] C.-L. WANG, P.C. YOUNG, Direct digital control by input-output, state variable feedback: theoretical background, International Journal of Control 47 (1988) 97-109. DOI:10.1080/00207178808905999

[26] C.L. Phillips, H.T. Nagle, Digital control system analysis and design, Prentice Hall Press2007.

[27] C. Taylor, A. Chotai, P. Young, Robust PIP control of multivariable stochastic systems, Robust Control: Theory, Software and Applications (Digest No: 1997/380), IEE Colloquium on, IET, 1997, pp. 2/1-2/3.

[28] J. Sadeghi, Modelling and Control of Non-linear Systems Using State-Dependent Parameter (SDP) Models and Proportional-Integral-Plus (PIP) Control Method., Ph.D Dissertation, Lancaster University, UK, 2006.

[29] Yao H., Chu J., Operational optimization of a simulated atmospheric distillation column using support vector regression models and information analysis, Chemical Engineering Research and Design, Vol. 90, pp. 2247-2261, 2012.

[30] F. Castillo, R. E. Hernández, and L. M. Sánchez, "Cost estimation for utilities in crude distillation units: A review of recent trends," AIChE Proceedings, pp. 1-10, 2023.