<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Optimizing the Design of a Hydrogen Refueling Station Integrating Renewable Energy and Seawater Desalination: A Case Study in Southern Iran</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>221</FirstPage>
			<LastPage>235</LastPage>
			<ELocationID EIdType="pii">9088</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2025.50666.1650</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Hamed</FirstName>
					<LastName>Maleki</LastName>
<Affiliation>Electrical Engineering Department, Shahid Beheshti University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad Sadegh</FirstName>
					<LastName>Sepasian</LastName>
<Affiliation>Electrical Engineering Department, Shahid Beheshti University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mohammad Reza</FirstName>
					<LastName>Aghamohammadi</LastName>
<Affiliation>Electrical Engineering Department, Shahid Beheshti University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mousa</FirstName>
					<LastName>Marzband</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia4
Center of Research Excellence in Renewable Energy and Power Systems, Department of Electrical and Computer Engineering, King
Abdulaziz University, Jeddah 21589, Saudi Arabia5</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>12</Month>
					<Day>31</Day>
				</PubDate>
			</History>
		<Abstract>This study investigates the optimal design configuration of a hydrogen refueling station located in southern Iran, focusing on the integration of renewable energy sources and seawater desalination technology to achieve self-sufficiency. The station integrates various components, including photovoltaic panels, fuel cells, desalination units, natural gas and power-to-hydrogen conversion systems, and storage facilities for water and hydrogen. The primary goals are to achieve an independent power supply from renewable sources and an autonomous water supply through seawater desalination. To determine the most cost-effective configuration, a Mixed Integer Linear Programming (MILP) model is developed, taking into account the water and power consumption of each component. The objective is to minimize the Net Present Cost (NPC) of investment, maintenance, and operation. The model is implemented and solved using the CBC solver within the PYOMO environment. The study&#039;s findings reveal that converting natural gas to hydrogen is more economically viable than power-to-hydrogen conversion, with the former accounting for more than 95% of the hydrogen produced. The power demand is effectively met by a combination of photovoltaic systems, fuel cells, and hydrogen storage. Moreover, the study highlights the benefits of integrating water and hydrogen storage systems, which optimizes the utilization of photovoltaic energy. Excess energy generated by the photovoltaic panels is utilized for seawater desalination and the production of green hydrogen</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Hydrogen refueling station</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">photovoltaic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Optimization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Water desalination</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_9088_74a5042140b3004286b6313338dc6bb0.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>On the Advance of Flyback CCM Control Strategies: a Comprehensive Review</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>237</FirstPage>
			<LastPage>246</LastPage>
			<ELocationID EIdType="pii">8765</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.50064.1628</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Saleh</FirstName>
					<LastName>Mohammadi</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Esfarayen university of technology, Esfarayen, North Khorasan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Hamid Reza</FirstName>
					<LastName>Izadfar</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Semnan university, Semnan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Naser</FirstName>
					<LastName>Eskandarian</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Semnan university, Semnan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>10</Month>
					<Day>20</Day>
				</PubDate>
			</History>
		<Abstract>This research aims to provide a comprehensive review of various CCM control strategies for flyback inverters. The study is carried out based on published data in reports, papers and other available online documents. The introduced control strategies make use of different approaches to dominate the constraints on determining the feedback control system gains caused by the zero put on right-half-plane (RHP) and dynamics of LC filter. Thus, the tracking of the considered output current is accurately implemented and the introduced control systems carry out the attenuation of disturbances. Moreover, zero steady-state error and the stability requirements are fulfilled by properly regulating the control signal. The best control structure should be enough fast employing the fewest number of delays in its structure resulting the burden in computational system to be considerably decreased.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Flyback micro-inverter</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">stability</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">photovoltaic (PV) system</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">right-half plane (RHP)</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_8765_1266fe53f1a85e6e9407952b26b30b74.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>A Setting-Free Loss of Excitation Detection of Synchronous Generator in the Presence of FACTs Device</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>247</FirstPage>
			<LastPage>253</LastPage>
			<ELocationID EIdType="pii">8779</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.49641.1612</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Milad</FirstName>
					<LastName>Niaz Azari</LastName>
<Affiliation>Department of Electrical Engineering, University of Science and Technology of Mazandaran, Behshahr, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Iraj</FirstName>
					<LastName>Ahmadi</LastName>
<Affiliation>Department of Electrical Engineering, University of Science and Technology of Mazandaran, Behshahr, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Hossein</FirstName>
					<LastName>Aboulqasemi</LastName>
<Affiliation>Department of Electrical Engineering, University of Science and Technology of Mazandaran, Behshahr, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>08</Day>
				</PubDate>
			</History>
		<Abstract>In this paper, the loss of excitation fault (LOE) as one of the most common fault in synchronous generator is analyzed and the methods for detecting this fault are investigated. Then, the performance of the power system equipped with STATCOM is simulated in the Matlab / Simulink software and the effects of the generator performance on the resistor and its derivatives in the generator terminal are analyzed. A new method for LOE detection based on derivative of resistance is proposed. To illustrate the efficiency of this method various sizes and conditions for generator load are considered. The simulation results show that the amount of resistance time derivative in all cases, whether with or without STATCOM, behaves the same as a new criterion for detecting the LOE of an effective and useful method that is faster and more accurate than conventional methods. Simulation results in different amount and type of the loads shows the validity of the proposed method.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Loss of Excitation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Derivative of the Resistance</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">STATCOM</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Stable Power Swing</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_8779_d29c89cd6ca1b6e578655c44a84cf5e6.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Diagnosis of Supercapacitor State-of-Charge in Electric Vehicle Applications using Artificial Neural Networks</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>255</FirstPage>
			<LastPage>263</LastPage>
			<ELocationID EIdType="pii">8918</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.48015.1542</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Seyed-Saeid</FirstName>
					<LastName>Moosavi-Anchehpoli</LastName>
<Affiliation>Clean power generation and Electrochemical laboratory, Amol University of Special Modern Technologies, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mahmood</FirstName>
					<LastName>Moghaddasian</LastName>
<Affiliation>Shohadaye Hoveizeh Campus of Technology, Shahid Chamran University of Ahvaz, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Maryam</FirstName>
					<LastName>Golpour</LastName>
<Affiliation>Clean power generation and Electrochemical laboratory, Amol University of Special Modern Technologies, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>02</Month>
					<Day>21</Day>
				</PubDate>
			</History>
		<Abstract>In an electric vehicle, energy storage systems (ESSs) are critical for sinking and sourcing power as well as ensuring operational protection. Because of their high power density, quick charging or discharging, and low internal loss, supercapacitors (SCs) are a recent addition to the types of energy storage units that can be used in an electric vehicle as an energy storage systems. They can be used in conjunction with batteries or fuel cells to create a hybrid energy storage device that maximizes the benefits of each component while minimizing the disadvantages. This paper presents a multilayer perceptrons (MLP) feedforward artificial neural network for supercapacitor state-of-charge diagnosis in vehicular applications. The proposed approach is tested using a supercapacitor Maxwel model that is subjected to complex charge and discharge current profiles as well as temperature changes. The proposed wavelet neural network and the validation results significantly improves state-of-charge estimation accuracy in different current discharge profiles.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">State-of-charge (SOC)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">wavelet transform (WT)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Artificial neural network (ANN)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Supercapacitor (SC)</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_8918_a130f93f061e8c0a825fd636e0175c0c.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Mobile Robot Localization in Indoor Environments Using Fuzzy Adaptive Unscented Kalman Filter and Random Tree Routing Algorithm with Fast Exploration</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>265</FirstPage>
			<LastPage>279</LastPage>
			<ELocationID EIdType="pii">8929</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.49234.1591</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Mohammadrasol</FirstName>
					<LastName>Hajali</LastName>
<Affiliation>Faculty of Electrical Engineering and Computer, University of Birjand, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ramezan</FirstName>
					<LastName>Havangi</LastName>
<Affiliation>Faculty of Electrical Engineering and Computer, University of Birjand, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>07</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		<Abstract>In the field of mobile robot navigation, challenges such as nonlinear conditions, uncertainties, and the development ‎of advanced methods have necessitated accurate position estimation. In this paper, fuzzy based adaptive ‎unscented Kalman filter (FAUKF) is evaluted to enhance the state estimation performance for mobile robot ‎localization. In proposed method, the FAUKF algorithm effectively removes the noise uncertainty by adaptively ‎adjusting the covariance of the measurement noise according to the adaptation law. The output of the Mamdani ‎Fuzzy Inference System (FIS) acts as an observer and improves the matching law. The results of this research show ‎the accuracy of FAUKF algorithm position estimation compared to traditional UKF methods. Also, this study ‎presents a pioneering navigation strategy for mobile robots, which integrates random tree routing algorithm with ‎rapid exploration (RRT*) for optimal path design in indoor environments. The goal of RRT* integration is to create ‎optimal routes taking into account safety and environmental constraints. By combining the Kalman filter ‎prediction and updating steps, this method reduces the accumulation of uncertainty during the localization process ‎and facilitates accurate localization and path planning towards the target.‎&lt;br /&gt;The simulation results confirm the effectiveness of this method in keeping the uncertainty levels in localization ‎constant over time. The presented adaptive method enables efficient navigation in complex environments. Path ‎planning is a critical element in robotics applications and the RRT* based approach presented in this paper provides ‎a comprehensive solution to create optimal and efficient paths.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Fuzzy</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">‎ Random tree routing ‎ Robot localization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">‎ Unscented Kalman filter</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_8929_947d4f5515595149231c33a09057de73.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Enhanced Speed Loop Control Strategy for Yokeless Axial FluxSwitching Permanent Magnet Motors</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>281</FirstPage>
			<LastPage>289</LastPage>
			<ELocationID EIdType="pii">8951</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.48867.1575</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Javad</FirstName>
					<LastName>Rahmanifard</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Qom University of Technology, Qom, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Saeed</FirstName>
					<LastName>Hasanzadeh</LastName>
<Affiliation>Department of Electrical and Computer Engineering, Qom University of Technology, Qom, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>05</Month>
					<Day>28</Day>
				</PubDate>
			</History>
		<Abstract>This paper presents an Enhanced Model-Free Sliding Mode Control (EMFSMC) method tailored for the speed loop of a 12-slot/19-pole yokeless and segmented armature axial flux-switching permanent magnet (12S/19P YASA-AFFSSPM) motor, focusing on robustness against parameter perturbations. Traditional control techniques, such as Proportional-Integral (PI) control and Model-Free Sliding Mode Control (MFSMC), have shown limitations in handling the motor&#039;s nonlinear behavior and susceptibility to disturbances. The proposed EMFSMC algorithm optimizes speed loop performance by establishing a hyperlocal model of the YASA-AFFSSPM motor, which accounts for parameter variations. An improved double-power combinatorial reaching law is developed to enhance convergence rates during the sliding surface approach phase, while an Extended Sliding Mode Disturbance Observer (ESMDO) provides real-time monitoring of unknown disturbances affecting speed control. Simulation results demonstrate that the EMFSMC significantly accelerates the speed response time to approximately 0.015 seconds with minimal overshoot, compared to 0.04 seconds and a 12.5% overshoot with the MFSMC. Additionally, under sudden load conditions, the EMFSMC controller exhibits a speed drop of only 4 rpm, recovering to stability in about 0.01 seconds, while the MFSMC controller experiences a 9 rpm drop with a recovery time of 0.03 seconds. These findings confirm that the EMFSMC enhances the speed response rate and robustness of the speed loop, outperforming traditional control methodologies across various operating conditions.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Flux-Switching motor</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">PM</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sliding Mode</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Model-free</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Observer</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_8951_dfcc5250af6df7682341fd300cbee94f.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Bidirectional High-Efficiency Converter Based on the Capacitive Wireless Power Transfer Technique for Electric Vehicle Charging and Energy Storage App</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>291</FirstPage>
			<LastPage>303</LastPage>
			<ELocationID EIdType="pii">8959</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.49629.1610</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Jasem</FirstName>
					<LastName>Shahsevani</LastName>
<Affiliation>Faculty of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Reza</FirstName>
					<LastName>Beiranvand</LastName>
<Affiliation>Faculty of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>08</Month>
					<Day>23</Day>
				</PubDate>
			</History>
		<Abstract>This article presents a transformer-less bidirectional converter, which is designed with dual resonant frequencies. It supports Electric Vehicle (EV) charging systems, via capacitive coupling wireless power transfer (CCWPT) technique. In addition, its bidirectional power transfer feature can be used to return energy to the stations of the power-wall systems. This converter smoothly operates in both voltage step-up and step-down operation modes, which provides soft switching conditions for all semiconductor switches. Capacitive coupling technique provides robust galvanic isolation between the primary and secondary sides circuits, while the transformer-less design improves its efficiency and reduces its volume and cost, significantly. The proposed converter supports both full-bridge and half-bridge configurations to adapt to diverse power transfer requirements. The cost-effective CCWPT setup enables multi-EV charging from a single station. A prototype of the given converter has been meticulously developed and experimentally validated, demonstrating excellent performance. The converter efficiently converts output power in a wide range from 200 W to 1000 W, accommodates input voltage from 300 to 500 V, delivers a 400 V output voltage, which is suitable for EV battery charging. It also achieves maximum efficiency value of 96%, in practice.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Capacitive wireless power transfer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electric vehicle charger</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Resonant conversion</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Step-up/down</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_8959_8e784f8c041a8a926f5b62412cdf3a7d.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Particle Filter Design for Fuel Temperature and Precursor Concentration Estimation under Different Power Conditions in a Nuclear Power Plant</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>305</FirstPage>
			<LastPage>315</LastPage>
			<ELocationID EIdType="pii">9045</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2025.50230.1633</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Hossein</FirstName>
					<LastName>Zahmatkesh</LastName>
<Affiliation>Faculty of Electrical and Computer Engineering, University of Birjand, Birjand, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Hussein</FirstName>
					<LastName>Eliasi</LastName>
<Affiliation>Faculty of Electrical and Computer Engineering, University of Birjand, Birjand, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>11</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		<Abstract>State estimation of nuclear reactors often plays a crucial role in accomplishing load-following control. This study presents a novel approach that leverages a weighted particle filter to address the challenges associated with estimating these crucial parameters, including relative precursor concentration (C_r) and fuel temperature (T_f), under varying reactor power conditions. A high-fidelity nonlinear dynamic reactor model was developed, incorporating noises in both process and measurement models. The proposed method was evaluated by extensive simulations under a wide range of operational scenarios. The particle filter demonstrated exceptional performance in tracking the time-varying states of the nuclear reactor. Comparative analysis with a conventional Kalman filter and the extended Kalman filter revealed the superior robustness of the particle filter in handling nonlinearities inherent in nuclear systems. The proposed approach offers several advantages, including the ability to capture multimodal distributions, handle non-Gaussian noise, and provide probabilistic estimates. Despite the increased computational cost associated with particle filtering, the benefits in terms of estimation accuracy and reliability justify its application in nuclear power plant monitoring and control systems.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Pressurized Water Reactor</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Precursors concentrations</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Kalman filter (KF)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Extended kalman filter (EKF)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Particle filter (PF)</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_9045_92133b1a1f01de14b7ded1fbd82071b7.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>A New Protection Strategy for Microgrid based on Integration of Active Power Index and Fault Current Differential Energy</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>317</FirstPage>
			<LastPage>332</LastPage>
			<ELocationID EIdType="pii">9101</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2024.49066.1597</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Reza</FirstName>
					<LastName>Karimi</LastName>
<Affiliation>Department of Electrical and Computer Engineering, University of Kashan, 6 km Ghotbravandi Blvd, Postal Code:
8731753153, Kashan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Abbas</FirstName>
					<LastName>Ketabi</LastName>
<Affiliation>Department of Electrical and Computer Engineering, University of Kashan, 6 km Ghotbravandi Blvd, Postal Code:
8731753153, Kashan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Seyyed Mohammad</FirstName>
					<LastName>Nobakhti</LastName>
<Affiliation>Department of Electrical Engineering, National University of Skills (NUS), Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>07</Month>
					<Day>27</Day>
				</PubDate>
			</History>
		<Abstract>The utilization of distributed generation (DG) sources in distribution systems has experienced significant growth due to their numerous advantages. Despite benefits such as voltage support and reduced losses, DG integration has introduced substantial challenges to distribution system protection, impairing the performance of conventional protection schemes. Variations in fault current levels, especially during islanding conditions, and bidirectional fault current flow are among the factors influencing the operation of traditional protection schemes. Under such conditions, directional overcurrent relays may not operate as intended. Moreover, coordinating multiple overcurrent relays is often challenging and can lead to increased operating times of protective relays. This paper proposes a directional comparison protection scheme for protecting lines and zones in active distribution systems based on the calculation of incremental active power transient energy. The proposed scheme is capable of detecting faults on microgrid lines at both low and medium voltage levels and is adaptable to changes in microgrid configuration. To prevent the directional protection scheme from operating during load switching transients, a differential protection scheme based on the calculation of transient energy of current signals is employed. The proposed methods offer the advantages of ease of calculation and high accuracy. An AC active distribution system incorporating inverter-based DG sources is implemented in the PSCAD-EMTDC software to simulate various fault types. The simulation results are then transferred to MATLAB for the implementation of the proposed algorithms.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Active power flowing</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Distributed Generation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Energy difference signal</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fault current direction</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Microgrid protection</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_9101_a2e8581c1404325b35471438c08f053f.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>University of Sistan and Baluchestan</PublisherName>
				<JournalTitle>International Journal of Industrial Electronics Control and Optimization</JournalTitle>
				<Issn>2645-3517</Issn>
				<Volume>8</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>09</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Novel Modeling and Nonlinear Control of the Siwakoti-H Inverter Considering Flying Capacitor Voltage Balance for Photovoltaic Applications</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>333</FirstPage>
			<LastPage>341</LastPage>
			<ELocationID EIdType="pii">9083</ELocationID>
			
<ELocationID EIdType="doi">10.22111/ieco.2025.50965.1658</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Amir M.</FirstName>
					<LastName>Mohamadi</LastName>
<Affiliation>Faculty of Engineering, Shahrekord University, Shahrekord, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Navid R.</FirstName>
					<LastName>Abjadi</LastName>
<Affiliation>Faculty of Engineering, Shahrekord University, Shahrekord, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Gholam Reza</FirstName>
					<LastName>Arab Markadeh</LastName>
<Affiliation>Department of Electrical Engineering, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>01</Month>
					<Day>31</Day>
				</PubDate>
			</History>
		<Abstract>The Siwakoti-H inverter (SHI) with a flying capacitor is a recent addition to the transformerless inverter family, suitable for grid-connected single-phase photovoltaic systems. It offers a promising alternative to traditional topologies without the need for transformers, due to its minimal power electronic components. However, one of the key challenges in managing flying capacitor (FC) inverters is ensuring that the voltage of the FC remains within the desired range. Materials and Methods: To tackle this issue, first, a novel nonlinear model of the SHI is obtained defining two control inputs and two control outputs, and then a nonlinear feedback linearization (FBL) control design is proposed for the SHI when connected to a single-phase grid. This article introduces a novel approach to the modeling and control of the SHI enabling simultaneous control of both the injected current to the grid and the flying capacitor voltage. The proposed modeling and the designed control method play a crucial role in maintaining the capacitor voltage within the specified range and in tracking a sinusoidal reference for the injected current into the single-phase network. A PWM implementation of the proposed control is also suggested which is useful in the practical setup. The obtained model can be extended for the SHI with other line filters and it can be used to design more sophisticated controllers for SHI. The simulation and practical results presented in this study demonstrate the effectiveness of the proposed modeling and control approach.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">feedback linearization</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">flying capacitor</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">photovoltaic</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Siwakoti-H inverter</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ieco.usb.ac.ir/article_9083_9c7e7df8967acd93e8b0fa1b648210a0.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
