Power systems
Javad Azarakhsh; Mahmoud Oukati Sadegh; Abdolhossein Mohammadrahimi
Abstract
Generator faults can partition shipboard microgrids into isolated zones, making energy storage system (ESS) placement as consequential as capacity for maintaining critical loads. This study jointly optimizes ESS placement and sizing in an eight-bus zonal shipboard microgrid, balancing cost, weight, and ...
Read More
Generator faults can partition shipboard microgrids into isolated zones, making energy storage system (ESS) placement as consequential as capacity for maintaining critical loads. This study jointly optimizes ESS placement and sizing in an eight-bus zonal shipboard microgrid, balancing cost, weight, and critical-load outage risk. Resilience is quantified using the conditional value-at-risk (CVaR) of a served-energy index under uncertain wind generation and demand. A conditional generative adversarial network produces fault-window scenarios with variability calibrated to historical data, while a neural-network surrogate replaces scenario-specific load-shedding computations within NSGA-II. The selected knee-point design locates storage in the critical forward zone, increasing worst-case resilience from 0.794 without ESS to 1.000. Because this design saturates the resilience objective at the full weight budget, statistical significance is evaluated using a representative, non-saturating sub-budget design at the same location. Relative to its own no-ESS baseline, this design improves worst-case resilience by 0.076 (95% CI [0.075, 0.078]); a paired Wilcoxon signed-rank test on matched per-scenario resilience indices yields p < 10⁻³⁴. The surrogate achieves a test R² of 0.871, with a maximum absolute error of 0.095 on a held-out subset of 50 designs, and accelerates objective evaluation approximately 1472-fold. Pareto-front stability across 20 random seeds is reflected in a hypervolume of 1.196 ± 0.002. These results demonstrate an efficient framework for storage planning that accounts for fault-induced isolation and uncertain operating conditions.
Power systems
Alireza Khatiri; Seyyed Yousef Mousazadeh Mousavi; Saeed Golestan
Abstract
Effective energy management in renewable-based microgrids demands advanced optimization and forecasting strategies capable of addressing the intrinsic uncertainties of solar generation and load demand. This paper proposes a comprehensive day-ahead scheduling framework based on Model Predictive Control ...
Read More
Effective energy management in renewable-based microgrids demands advanced optimization and forecasting strategies capable of addressing the intrinsic uncertainties of solar generation and load demand. This paper proposes a comprehensive day-ahead scheduling framework based on Model Predictive Control (MPC) to enhance the operational efficiency of a grid-connected microgrid comprising photovoltaic units, microturbines, fuel cells, and battery energy storage. The MPC structure incorporates 24-hour-ahead forecasts of load and solar irradiance generated through multiple deep learning architectures, enabling dynamic adaptation to rapidly changing environmental and consumption conditions. To solve the underlying optimization problem, a novel Quadratic Interpolation Optimization (QIO) algorithm is employed, offering improved convergence behavior and robustness in comparison with conventional metaheuristic methods. The integrated forecasting–optimization methodology ensures optimal dispatch of distributed resources, effective utilization of storage systems, and economically efficient power exchange with the utility grid. Extensive simulations validate the superiority of the proposed MPC-QIO framework in reducing operational costs, enhancing renewable energy penetration, and maintaining system reliability even under forecasting uncertainties. The results confirm that the synergy between deep learning-based prediction and advanced optimization significantly strengthens the controllability and resilience of modern microgrids, highlighting the method’s strong potential for real-world deployment.
Optimization
Hamid Karimi; Hamid Reza Sezavar
Abstract
This paper presents a multi-objective energy management strategy for a hybrid electricity-hydrogen microgrid (MG) aimed at improving economic and operational performance. The proposed framework simultaneously minimizes total operating cost and reduces peak load, which are conflicting objectives in MG ...
Read More
This paper presents a multi-objective energy management strategy for a hybrid electricity-hydrogen microgrid (MG) aimed at improving economic and operational performance. The proposed framework simultaneously minimizes total operating cost and reduces peak load, which are conflicting objectives in MG operation. To address this challenge, the problem is formulated as a multi-objective optimization model using a normalized weighted sum approach, enabling an effective trade-off between objectives while preventing the creation of new peaks in the load profile. The studied hydrogen-based MGs includes renewable energy sources such as solar and wind power, a battery energy storage system (BESS), a diesel generator, and demand response programs. Hydrogen is also utilized as an energy carrier to enhance system flexibility and support improved integration of renewable generation. Coordinated scheduling of generation units, storage systems, and flexible loads improves system efficiency. To enhance model accuracy, a long short-term memory (LSTM) forecasting method is applied to predict solar irradiance and wind speed using historical data, supporting more reliable scheduling decisions. The proposed model is validated through a general case study. Simulation results show a peak load reduction of 442 kW and an improvement in the load factor of 16.75%, confirming the effectiveness of the proposed approach
Power systems
Navid Reza Abjadi
Abstract
Due to the growth of renewable energies and the need for sustainable electrical energy, AC microgrids (MGs) have been the subject of intense research. Medium voltage MGs will soon have a special place in the power industry. This paper uses a new and effective control scheme for islanded inverter-based ...
Read More
Due to the growth of renewable energies and the need for sustainable electrical energy, AC microgrids (MGs) have been the subject of intense research. Medium voltage MGs will soon have a special place in the power industry. This paper uses a new and effective control scheme for islanded inverter-based medium voltage MGs using the master-slave (MS) technique. The controllers only need local measurements. The designed controls are based on adaptive input-output feedback linearization control (AIOFLC). These controls have a high-performance response; and are robust against some uncertainties and disturbances. The use of the designed control scheme makes the output voltage of distributed generation (DG) sources have negligible harmonics. Besides, the generated voltage and active/reactive powers track their references effectively. The model of the inverter-based DGs is considered in a stationary reference frame, and there is no need for any coordinate frame transformation. The control method presented in this paper can be used for MGs with any number of inverter-based DGs and parallel inverters. The effectiveness of the proposed control scheme is evaluated by simulation in SIMULINK/MATLAB environment and compared with that of feedback linearization control (FLC) and conventional sliding mode control (CSMC).
Power systems
Hamed Sadeghi; Hamid Reza Mohammadi
Abstract
Electric spring (ES) is a new technology that can be used for fast demand-side management to balance the power between generation and consumption in smart grids. In this paper, the back-to-back structure of electric spring is controlled to operate simultaneously as electric spring and shunt active power ...
Read More
Electric spring (ES) is a new technology that can be used for fast demand-side management to balance the power between generation and consumption in smart grids. In this paper, the back-to-back structure of electric spring is controlled to operate simultaneously as electric spring and shunt active power filter (shunt-APF). That means the series part of the back-to-back electric spring regulates the critical load voltage and applies the demand-side management and the parallel part operates as a shunt active power filter capable of power factor correction and current harmonic compensation. In the proposed structure, due to harmonic compensation and power factor improvement by the parallel inverter, the output power capacity of the electric spring is increased compared with the first and second generation of electric springs (ES-1 and ES-2), and the performance is improved in critical conditions. Additionally, to improve the robustness of the control system against uncertainties in the grid system, two fuzzy logic controllers are designed to control the voltage of the electric spring and the DC link voltage. The theoretical analysis is validated by simulation results using MATLAB/SIMULINK software.
Power systems
Ali Sefidgar-dezfouli; Mahmood Joorabian; Elaheh Mashhour
Abstract
This paper deals with the optimal scheduling of a microgrid (MG) equipped with dispatchable distributed generators (DGs), renewable generators and electrical storages (batteries). A chance-constrained model is developed to handle normal operation and emergency conditions of MG including DG outage and ...
Read More
This paper deals with the optimal scheduling of a microgrid (MG) equipped with dispatchable distributed generators (DGs), renewable generators and electrical storages (batteries). A chance-constrained model is developed to handle normal operation and emergency conditions of MG including DG outage and unwanted islanding. Purchasing reserve from the upstream grid is also considered. Moreover, the uncertainties of loads and renewable resources are incorporated into the model. Furthermore, a novel probabilistic formulation is presented to determine the amount of required reserve in different conditions of MG by introducing separate probability distribution functions (PDFs) for each condition. Accordingly, an index named as the probability of reserve sufficiency (PRS) is introduced. The presented model keeps a given value of PRS in normal and emergency conditions of MG operation. In addition, some controllable variables are added to the chance constraints as an innovative technique to reduce the complexity of the model. Finally, a test microgrid is studied in different case studies and the results are evaluated.
Power systems
Akbar Karimipouya; Shahram Karimi; Hamdi Abdi
Abstract
the main challenge in associate islanded Micro grid (MG) is the frequency stability due to the inherent low-inertia feature of distributed energy resources. That is why, energy storage devices, are utilized in MGs as the promising sources for grid short-term frequency regulation. Though energy storage ...
Read More
the main challenge in associate islanded Micro grid (MG) is the frequency stability due to the inherent low-inertia feature of distributed energy resources. That is why, energy storage devices, are utilized in MGs as the promising sources for grid short-term frequency regulation. Though energy storage devices, improve the dynamic response of the load frequency control system, these devices increase system costs. Moreover, the modification or uncertainty of the system parameters will significantly degrade the performance of the conventional load-frequency control system. This article proposes the implementation of rotating-mass-based virtual inertia in Double-Fed Induction Generator (DFIG) to support the primary frequency control associated an adaptive Neuro-Fuzzy Inference System (ANFIS) controller, as the secondary frequency control. The simulation results illustrate that the suggested control scheme ameliorate the dynamic response and performance of the load frequency control system and also the studied islanded MG remains stable, despite severe load variation and parametric uncertainties.
Power systems
Reza Sedaghati; Mahmoud Reza Shakarami
Abstract
A single-phase distributed generation (DG) sources embedded in three-phase microgrids develop with a fast-paced trend, it is important to make use of suitable power sharing strategies among multiple DGs and utilizing the power generation of these units to the full capacity. This paper presents an innovative ...
Read More
A single-phase distributed generation (DG) sources embedded in three-phase microgrids develop with a fast-paced trend, it is important to make use of suitable power sharing strategies among multiple DGs and utilizing the power generation of these units to the full capacity. This paper presents an innovative sliding mode-based power control strategy for microgrids. The multi-bus microgrid consists of three-phase DG units that are two photovoltaic (PV) array, and three single-phase DG units including PV, battery and fuel cell (FC). The dynamic modeling of all DGs is based on voltage source inverter (VSI). One of the three-phase DGs is responsible for frequency and voltage control, and the other one for current control. The single-phase DGs are controlled based on the three-phase DGs. Finally, the voltage and power control operations are implemented in a per-unit system. The proposed control strategy has a fast response and the ability to trace a reference signal with a low steady-state error compared with the PI controller; moreover, it provides the accurate active and reactive power sharing among energy units under various loading and fault conditions along with robustness against the microgrid parameters. Additionally, the ability to maintain the dc-link voltage and frequency constant is another feature of this controller.
Power systems
Mehrdad Ahmadi Kamarposhti
Abstract
Microgrid is defined as a controllable unit which consists of Distributed Generations (DG), loads, energy storages and control devices. Microgrid has two operation modes including grid connected mode and islanding mode. In grid connected mode, voltage and frequency of microgrid is controlled by main ...
Read More
Microgrid is defined as a controllable unit which consists of Distributed Generations (DG), loads, energy storages and control devices. Microgrid has two operation modes including grid connected mode and islanding mode. In grid connected mode, voltage and frequency of microgrid is controlled by main grid and DG’s supply total or part of the loads. In the islanding mode, the microgrid is disconnected from main grid because of a fault or a preplanned switching in connecting line. In this mode, DG’s should satisfy the power demand of sensitive loads in microgrid. Since the only generation units in an islanded microgrid are existing DG units which usually are from several types. Consequently besides feeding total loads, voltage and frequency of microgrid should be controlled by these DG units. Hence, the microgrid could supply high power quality and reliability to customers. This paper presents an optimization method to optimize the parameters of the Microgrid controller in islanding mode. The controller optimal parameters have been obtained by using the particle swarm optimization (PSO). This is done based on minimization of the error in the current and voltage controllers. Finally, simulation has been carried out to verify the effectiveness of the optimized controller. Stability analysis of the controller is verified using classical approach.