Power systems
Javad Azarakhsh; Mahmoud Oukati Sadegh; Abdolhossein Mohammadrahimi
Abstract
Generator faults can partition shipboard microgrids into isolated zones, making energy storage system (ESS) placement as consequential as capacity for maintaining critical loads. This study jointly optimizes ESS placement and sizing in an eight-bus zonal shipboard microgrid, balancing cost, weight, and ...
Read More
Generator faults can partition shipboard microgrids into isolated zones, making energy storage system (ESS) placement as consequential as capacity for maintaining critical loads. This study jointly optimizes ESS placement and sizing in an eight-bus zonal shipboard microgrid, balancing cost, weight, and critical-load outage risk. Resilience is quantified using the conditional value-at-risk (CVaR) of a served-energy index under uncertain wind generation and demand. A conditional generative adversarial network produces fault-window scenarios with variability calibrated to historical data, while a neural-network surrogate replaces scenario-specific load-shedding computations within NSGA-II. The selected knee-point design locates storage in the critical forward zone, increasing worst-case resilience from 0.794 without ESS to 1.000. Because this design saturates the resilience objective at the full weight budget, statistical significance is evaluated using a representative, non-saturating sub-budget design at the same location. Relative to its own no-ESS baseline, this design improves worst-case resilience by 0.076 (95% CI [0.075, 0.078]); a paired Wilcoxon signed-rank test on matched per-scenario resilience indices yields p < 10⁻³⁴. The surrogate achieves a test R² of 0.871, with a maximum absolute error of 0.095 on a held-out subset of 50 designs, and accelerates objective evaluation approximately 1472-fold. Pareto-front stability across 20 random seeds is reflected in a hypervolume of 1.196 ± 0.002. These results demonstrate an efficient framework for storage planning that accounts for fault-induced isolation and uncertain operating conditions.
Power systems
Ali Riki; Mahmoud Oukati Sadegh; Omid Narouei
Abstract
The concept of an energy hub (EH) has been utilized to address the issue of performing concurrent operations of various energy generation and transmission infrastructures. One of the primary concerns for investors is the efficient utilization of EH to effectively manage energy carriers, particularly ...
Read More
The concept of an energy hub (EH) has been utilized to address the issue of performing concurrent operations of various energy generation and transmission infrastructures. One of the primary concerns for investors is the efficient utilization of EH to effectively manage energy carriers, particularly in transactions with the upstream grid. In this paper the proposed smart energy hubs (SEH) manage dispatchable generation, i.e. Combined Cooling, Heat, and power (CCHP), and non-dispatchable generation, i.e. Photovoltaic (PV). SEHs consider Ice Storage Conditioner (ISC) as well as Thermal Energy Storage System (TESS) as the Energy Storage System (ESS). To mitigate dependence on gas and electricity utility companies, a peer-to-peer (P2P) energy sharing strategy has been executed. The implementation of demand response (DR) is directed toward shiftable electrical loads. The thermodynamic model of heating and cooling loads is developed with flexibility as integrated demand response (IDR) based on the desired temperature. The objective of optimization is to minimize operation and environmental costs.. The flexibility constraint serves in particular to enhance the flexibility of the interrelationships between MG and the upstream network. The suggested model incorporates the probabilistic nature of PV generation as well as the electrical, thermal, and cooling demands in various scenarios. The proposed model is a Mix Integer Non-Linear Problem (MINLP), which was solved using SCIP solver in GAMS software. Implementation of the proposed framework on the typical EHs shows the impact of P2P transactive energy and flexibility constraint performance on elements such as operation costs, emissions and flexibility of the system.
Power systems
Reza Safipour; Mahmoud Oukati Sadegh
Abstract
Energy storage systems, along with many capabilities in the grid, are costly technologies. Therefore, their economic issues should be also considered while they are used in the grid. In this paper, a method has been proposed that can be used to determine the location, power, and capacity of the energy ...
Read More
Energy storage systems, along with many capabilities in the grid, are costly technologies. Therefore, their economic issues should be also considered while they are used in the grid. In this paper, a method has been proposed that can be used to determine the location, power, and capacity of the energy storage systems with consideration of the technical and economic aspects, simultaneously. Technical goals of this method are improvement of voltage profile and loss reduction, while economic objectives are including reduction of investment cost, operation and maintenance cost of the energy storage system. The problem of optimization is solved with the symbiotic organisms search algorithm. The main advantage of this algorithm is the absence of specific regulatory parameters compared to other meta-heuristic algorithms. The proposed plan has been implemented safely. Safe performance is achieved by enforcing security constraints such as voltage and power balancing and constraints for the energy storage system, such as capacity of energy and power constraints, and amount of energy stored. The distributed generation used in this plan is wind power plant. The output of each turbine is determined by a linear model reliant on wind speed. The proposed method has been implemented on the IEEE 33 bus grid. The results demonstrate the efficiency and capability of the proposed method.